| Specifications |
| Probe |
| Material: |
Stainless Steel |
| Detector: |
Pyrex glass with platinum electrodes |
| Flue Gas Temperature: |
0 to 400º C / 32 to 750º F |
| Length: |
1.2m . 4 ft standard |
| Weight (Probe): |
2.4 kg / 5.3 lb |
| Weight (M'ting Tube): |
3.9kg / 8.6 lb |
| Mounting Flange: |
Land supplied |
| Electronic Control Unit (ECU) |
| Electronics: |
Microprocessor based |
| Selectable Display: |
Sulphuric Acid Dewpoint Temperature, RBU,
Ambient Temperature, MMT, Current, SO3 |
| Output: |
2 current 4 - 20mA
(0 to 260º C / 0 to 500º F) |
| Accuracy: |
+2º C / + 4º F |
| Operating Temperature: |
0 to 50º C / 32 to 120º F |
| Input Air Supply: |
3 litres/sec / 6 cfm |
| AC Supply: |
110/240V a.c. 50/60Hz |
| Alarms / Relays: |
Maintenance / Fault
One common relay |
| Enclosure: |
IP65 / NEMA 4 |
| Weight: |
18 kg / 38 lb |
| Dimensions: |
600 x 380 x 210 mm/
23.6 x 15 x 8.3 inches |
| Air Flow Regulator and Detector Cleaning System (ACU) |
| Enclosure: |
IP65 / NEMA 4 |
| Air Flow Rate: |
3 litres/sec / 6 cfm |
| Air Pressure: |
60 to 100 psi / 4 to 7 bar |
| Operating Temperature: |
0 to 65º C / 32 to 160º F |
| Water Flow Rate: |
4 litres/day maximum usage |
| Water Pressure: |
20 psi / 1.4 bar |
| Dimensions: |
600 x 600 x 210mm
23.6 x 23.8 x 8.6 inches |
| Weight: |
29.5 kg / 65 lb |