| Specifications |
|
Species Measured
|
Single Species
Minimum Full Scale
|
Multi-Species
Minimum Full Scale
|
|
SO2
|
25 ppm
|
50 ppm
|
|
H2S
|
50 ppm
|
100 ppm
|
|
NO
|
50 ppm
|
200 ppm*
|
|
NO2
|
100 ppm
|
200 ppm*
|
|
NOx
|
n/a
|
200 ppm*
|
|
* Lower ranges available upon request
|
|
| Maximum full scale on all systems: |
100% |
| Methodology: |
Multiple wavelength, high resolution, non-dispersive ultraviolet |
| Optional O2: |
Integral paramagnetic sensor |
| Accuracy: |
Better than 1.0% of standard full scale range O2 : ±0.1% |
| Repeatability: |
±0.5% full-scale of standard ranges O2 : ±0.2% (reading varies by 0.05% due to A/D resolution) |
| Linearity: |
SO2: < ±1.0% full scale
NO, NO2, NOx, H2S: < ±1.5% full scale
O2: ±0.1% |
| Response Time: |
90% in 30 seconds or less |
| Number of Gases: |
1 (single species version)
Up to 5 (multi-species version) |
| Typical Sample Flow: |
0.25 - 5 l/min (0.6 - 10.5 SCFH) |
| Sample Gas Requirements: |
Noncorrosive, non-condensing, free from oil and with less than three micron particulates (0-95%, non-condensing) |
| Sample System Limits: |
5 psig max (without the dynamic pressure compensation option, the reported concentrations will be directly proportional to barometric pressure) |
| Pressure and Temperature Compensation: |
Optional |
| Ambient Conditions |
| Storage: |
-40 to 70˚C (-40 to 158˚F) |
| Operating: |
-20 to 50˚C (-4 to 122˚F) without Paramagnetic O2 sensor, 0 to 50˚C (32 to 122˚F) with Paramagnetic O2 sensor 0.95 Relative Humidity |
| Zero Drift: |
Typically better than 2% full scale standard ranges in 24 hours |
| Utility Requirements |
| Electrical: |
120 VAC (105 to 132 VAC), 47 to 63 Hz
240 VAC (209 to 264 VAC), 47 to 63 Hz |
| Power Consumption: |
< 300 W maximum start-up (from a cold start) with average power dependant on ambient temperature |
| Outputs: |
Two (expandable to six) isolated Analog Outputs, each configurable to 0-20 mA, 4-20 mA, 0-5V DC
Four (expandable to six) Relay Contacts, Contact Form A (SPST), normally open. Switching: maximum 240 V DC, 0.5 A DC, limited to 10 W.
Carry: maximum 1.2 A DC Four optional solenoid drivers 24 V DC 0.5A max. |
| Inputs: |
Two optional isolated analog inputs, each configurable to 0-5 Volts or 0-20 mA.
Two (expandable to four) contact inputs, each pair isolated from analyzer. Voltage 5 V DC unregulated.
Current approx. 7 mA. |
| Communications: |
Modbus RTU RS485 and Modbus TCP
Fast Ethernet - network connection or web-based server |
| Physical Dimensions (W x H x D): |
48.2 cm x 17.7 cm x 60.256 cm (19 in. x 7 in. x 23.7 in.) |
| Weight: |
18.2 kg (40 lb) |