Model 919 Hot/Wet Gas Analyzer

Model 919 Hot/Wet Single Gas Analyzer
Overview

The Model 919 is specifically configured for monitoring stack emissions on a concentration basis. With the addition of an optional zirconium oxide sensor, the Model 919 is capable of monitoring oxygen.

Robust and reliable analyzer, the Model 919 has no-moving-parts, UV-based measurements do not suffer from H2O and CO2 interference. This greatly simplifies sample handling and sample integrity as there is no need for sample drying. As a fully extractive, heated wet basis analyzer, the 919's sample system components are simply heated above the dew point of the sample gas. This results in a simpler and more accurate calculation of gas concentration, requiring no corrections for condensed and dissolved components.

The Model 919 performs all necessary sample gas and calibration gas flow management, and probe and sample line temperature control. The Model 919 is a full function Continuous Emissions Monitoring System (CEM) which requires the addition of only a sample probe and sample line to be fully operational. Housing options for the analyzer include a cabinet or walk in shelter built to your specifications.

Features
  • High reliability and reduced maintenance requirements through a no moving parts design
  • Hot/wet analysis prevents errors associated with:
  • Correcting for water vapor
  • Absorption losses in driers
  • Accuracy better than 2.5 ppm SO2
  • Able to measure SO2, NO, NO2, H2S, NH3 or a number of other chemicals
  • No H2O or CO2 interference
  • Automated zero and span gas calibration
  • Provides serial interface with plant DCS

Other Product of Interest:

  • Specifications +


    Methodology:Dual wavelength, high resolution, nondispersive UV
    Species Measured Minimum Full Scale† Maximum Full Scale
    SO2 250 ppm 100%
    NO 300 ppm 100%
    NO2 300ppm 100%
    H2S 500 ppm 100%
    NH3 125 ppm 100%
    Cl2 500 ppm 100%
    Accuracy Better than 1% full scale
    Reproducibility Better than 0.5% full scale
    Response Time Typically less than 30s to T90 (excludes sample system)
    Sample Transport Air aspiration
    Typical Sample Flow 3 to 5 L/min (0.1 to 0.2 CFM)
    Temperature Control Independent control of up to five zones
    Pressure and Temperature Compensation Standard
    Ambient Temperature* 5° to 50°C (41° to 122°F)
    Instrument Air Minimum 413.6 KPa (60 psig), 120 L/min (4.24 CFM), instrument quality air
    Power 120 VAC ±10%, 47-63 Hz or 240 VAC ±10%, 47-63 Hz 600 W for analyzer only
    Communications
    Analog 4 x 4-to-20 mA self-powered
    Digital One RS232 port for service diagnostics
    One RS422 with Modbus protocol
    Relays 3 independent sets of SPDT relays alarm conditions
    Physical Dimensions 1553.6 x 1117.6 x 306 mm (61.17 x 44 x 12 in.)
    Weight Estimated minimum 160 kg (350 lbs.)
    Approvals and Certifications NEC/CEC Class I, Division 2, Groups C & D
    ATEX II 2G EEx pd IIB T3
    Russian Ex Proof Certification; 1ExpydIIBT3
    Russian Gosstandard Pattern Approval
    Complies with all relevant European Directives
    * Temperature drift is approximately 1 ppm/˚C for the species listed. To achieve maximum accuracy and stability, you can either install the analyzer in a temperature-controlled environment or zero the analyzer more frequently.
  • Documents +

  • Certifications +


    • NEC/CEC Class I, Division 2, Groups C & D
    • ATEX II 2G EEx pd IIB T3
    • Russian Ex Proof Certification; 1ExpydIIBT3
    • Russian Gosstandard Pattern Approval
    • Complies with all relevant European Directives
  • Applications +


    Applications
    • Sulfur Plants
    • Smelters
    • Power Plants
    • Industrial Boilers
    • Process Heater