Zirconia Oxygen Analyzers

  • THERMOX Model  WDG-V Combustion Analyzer
    THERMOX Model WDG-V Combustion Analyzer

    Low emission burners and aggressive firing control points to achieve increased efficiency and emission reductions have driven the industry to tighter control measures. But tighter control measures also hold a greater potential for combustion events. Reducing the risk of a combustion event has become a priority and has led to the implementation of Safety Instrumented Systems (SIS). This additional layer of safety is added to the Basic Process Control System.

    Keep Reading
  • Model WDG-V Zone1
    Model WDG-V Zone1

    The Thermox® WDG-V combustion analyzer from AMETEK Process Instruments has been third-party certified for Zone 1 hazardous locations, allowing the unit to operate in areas in which hazardous vapors and gases will continuously be present.

    Keep Reading
  • Model WDG-IV Series Analyzers
    Model WDG-IV Series Analyzers

    The WDG-IV analyzer measures oxygen, combustibles and methane in natural gas-fired applications. It is ideal for gas-fired power boilers or for those using natural gas during start-up and shutdown. With this analyzer, you can monitor oxygen and combustibles for maximum fuel efficiency. Available with Series 2000 controller or integrated /IQ electronics.

    Keep Reading
  • Model WDG HP Analyzer
    Model WDG-HPII Analyzer

    The WDG-HPII Series offers a unique chimney-effect/convective sampling technology that incorporates the advantages of insitu probe high particulate sampling with high temperature and corrosion resistance of extractive analyzers. The HPII is ideal for combustibles and oxygen measurement on applications in cement and lime kilns, foundry and metals production furnaces, coal, wood waste and heavy oil-fired boilers, black liquor recovery boilers. Available with Series 2000 controller or integrated /IQ electronics

    Keep Reading
  • Model CEM Oxygen Analyzer
    Model CEM Oxygen Analyzer

    Continuous Emissions Monitoring systems using hot-wet extractive systems take the flue gas sample from the exit of wet-scrubbers. A hot-wet oxygen measurement is taken from the incoming feed line to the CEM system analysis cabinet. The oxygen analyzer used for this measurement must be equipped to keep the sample gas above the dew point and compact to fit within the restricted space of the analysis cabinet.

    Keep Reading
  • Model CG1100 Oxygen Analyzer
    Model CG1100 Oxygen Analyzer

    The CG1100 is equipped with an RS-232 and two RS-485 ports: It comes with configurator software for initial setup of operating parameters and accepts user-provided software for efficient integration with a host controller, or Dycor System 2000 software to record and process data.

    Keep Reading
  • Model CMFA-P2000
    Model CMFA-P2000

    Versatile precombustion or flue gas analyzer commonly used for spot sampling glass melting tanks, mix station tuning on forehearths, furnace atmosphere control, and for flame treating applications.

    Keep Reading
  • Model PreMix 2000
    Model PreMix 2000

    Forehearth zone temperature is critical to proper flow of molten glass to fiber forming equipment. The combustion atmosphere in fiber forming baskets is equally important to ensure fiber quality and consistancy. Forehearth zone temperature and fiber forming atmosphere are both controlled by adjusting the air to fuel ratio of discrete premix burner stations feeding these systems. Continuous analysis of resultant excess oxygen or excess fuel from air to fuel ratio adjustments is needed to automate the glass fiber manufacturing process.

    Keep Reading
  • Model TM2000 Oxygen Analyzer
    Model TM2000 Oxygen Analyzer

    The TM2000 Net Oxygen Analyzer protects industrial processes by quickly responding to changes using an industry proven zirconium oxide sensor. It operates within a wide range of 0.1 ppm to 100% oxygen, and can accurately respond from atmosphere to low ppm oxygen levels in just seconds. In addition, the TM2000 can detect excess combustibles process upsets in the presence of very low ppm oxygen readings. This unique benefit is particularly important in cryogenic gas generating processes, where the TM2000 can distinguish between an oxygen upset condition and an excess combustibles upset condition.

    Keep Reading
  • THERMOX  Model WDG 1200 Insitu
    Model WDG 1200 Insitu

    The WDG 1200 Insitu and the WDG 1210 Insitu are rugged, reliable flue gas analyzers for net oxygen that use industry-proven zirconium oxide sensor technology. The outer probe tube is 310 stainless steel so no abrasion shield is needed for most applications. The controller features precision temperature control for optimum stability, built-in diagnostics, and over-temperature protection. Modbus and 4-20 mA outputs are standard; automatic calibration is available. The unique sensor design allows the entire sensor assembly, including the heater, to be removed without disturbing the outer protection tube which remains in the process. This makes field service fast and easy, and because there is no need to return the probe to the factory for repair, there’s no expensive downtime.

    Keep Reading
  • Model WDG Insitu Probe
    Model WDG Insitu Probe

    Modern gas, oil and coal fired boiler operations require dependable, low-maintanence, application flexible devices to monitor and control combustion processes. The measurement of excess oxygen in flue gas is particularly important for obtaining maximum combustion fuel efficiency while minimizing thermal or fuel-bound Nitrogen oxides generation. The zirconium oxide insitu probe has become the industry standard for making this flue gas-oxygen measurement. However, most insitu probe designs do not afford ideal accessibility to filter, cell and heater components, requiring removal of the probe from the process flange for servicing.

    Keep Reading
  • WDG-IV UOP/RP
    Model WDG-IV UOP/RP Analyzer

    The UOP Continuous Catalyst Regeneration Process requires low-level continuous oxygen measurement during the regeneration process to protect the Platonized catalyst from oxidation. The process is operated at elevated temperature and pressure. The flue gas contains low levels of HCL and catalyst fines. The critical oxygen measurement analyzer must be able to survive the veracious nature of the process while maintaining a high level of accuracy at low level oxygen concentrations.

    Keep Reading
  • Model CG1000 Oxygen Analyzer
    Model CG1000 Oxygen Analyzer

    The CG1000 is a portable oxygen analyzer designed for industrial and laboratory applications. It has a wide operating range (0.1 ppm to 100% O2, autoranging), a fast response to oxygen changes, and advanced electronic capabilities for easy system integration.

    Keep Reading