Search


Home

Our Applications Our-Products Our Technology
Path: Home>Technology>Technology Search Results
CEM/O2

Large municipal waste water treatment facilities operate sludge incinerators to dispose of insoluble materials extracted from the digester and clarifier solids traps. Continuous Emissions Monitoring systems applied to waste water sludge incinerators are typically hot-wet extractive systems that take the flue gas sample from the exit of wet-scrubbers. A hot-wet Oxygen measurement is taken from the incoming feed line to the CEM system analysis cabinet. The oxygen analyzer used for this measurement must be equipped to keep the sample gas above the dew point and compact to fit within the restricted space of the analysis cabinet. more ...


CG1100 Oxygen Analyzer

Fast Response over a Wide Operating Range: Your system will respond rapidly over an operating range of 0.1 ppm to 100% oxygen. Easy to Integrate into Your Host Controller and Data Acquisition System: The CG1100 is equipped with an RS-232 and two RS-485 ports: It ocmes with configurator software for initial setup of operating parameters and accepts user-provided software for efficient integration with a host controller, or Dycor System 2000 software to record and process data.more ...


CMFA-P CMFA-P2000

Combustion gas measurements for NOX efficiency and product quality are especially challenging in the glass container manufacturing process. Two types of gas-fired furnaces exist that require post and pre combustion gas analysis. The glass furnace or "melt-tank" is fired by conventional burners that mix pre-heated air and fuel in the burner nozzle. Ambient air leakage in the heat re-cooperation structure can generate thermal NOX in the combustion flames while creating significant thermal energy losses. Flue gas temperature and vaporized glass particulates limit economical excess oxygen analysis to spot sample measurements at opposing-burner checker ports. more ...


Insitu Replacement Probes

Removing an oxygen insitu probe from any combustion process is a time consuming and costly task. Periodic removal of insitu probes is required to protect zirconium oxide cells from chemical washdown operations while higher blends and increased use of high ash and lower sulfur PRB coals require more frequent removal of probes to clean plugged filters. more ...


PreMix 2000

Forehearth zone temperature is critical to proper flow of molten glass to fiber forming equipment. The combustion atmosphere in fiber forming baskets is equally important to ensure fiber quality and consistancy. Forehearth zone temperature and fiber forming atmosphere are both controlled by adjusting the air to fuel ratio of descrete premix burner stations feeding these systems. Continuous analysis of resultant excess oxygen or excess fuel from air to fuel ratio adjustments is needed to automate the glass fiber manufacturing process. more ...


S A/F IQ S A/F IQ

Waste gas, biogas, off-gas, blast furnace and coke oven gas are often used as fuel for boilers, reboilers, furnaces, gas turbines and incinerators. The highly variable BTU content makes it difficult to use these fuels efficiently, safely and with minimum emissions. This analyzer directly measures the flow of air needed to burn a flow of a variable composition fuel gas. It can be used to compensate for the non-uniformity in gas supplies and to aid in the efficient utilization of by-product and waste-gas streams as fuel. more ...


TM2000 TM2000 Oxygen Analyzer

The TM2000 net oxygen analyzer protects industrial processes by quickly responding to changes using an industry proven zirconium oxide sensor. It operates within a wide range of 0.1 ppm to 100% oxygen, and can accurately respond from atmosphere to low ppm oxygen levels in just seconds.more ...


WDG 1200 Insitu

The WDG 1200/Insitu and the WDG 1210/Insitu are rugged, reliable flue gas analyzers for net oxygen that use industry-proven zirconium oxide sensor technology. more ...


WDG Insitu Probe

Modern gas, oil and coal fired boiler operations require dependable, low-maintanence, application flexible devices to monitor and control combustion processes. The measurement of excess oxygen in flue gas is particularly important for obtaining maximum combustion fuel efficiency while minimizing thermal or fuel-bound Nitrogen oxides generation. The zirconium oxide insitu probe has become the industry standard for making this flue gas-oxygen measurement. However most insitu probe designs do not afford ideal accessibility to filter, cell and heater components, requiring removal of the probe from the process flange for servicing. more ...


WDG-HPIICM IQ WDG-HPII

The WDG-HPII Series offers a unique chimney-effect/convective sampling technology that incorporates the advantages of insitu probe high particulate sampling with high temperature and corrosion resistance of extractive analyzers. The HPIIC is ideal for Combustibles and oxygen measurement on applications in cement and lime kilns, foundry and metals production furnaces, coal, wood waste and heavy oil-fired boilers, black liquor recovery boilers.more ...


WDG-IVCM IQ WDG-IV Products

The WDG-IV analyzer measures oxygen, combustibles and methane in natural gas-fired applications. It is ideal for gas-fired power boilers or for those using natural gas during start-up and shutdown. With this analyzer, you can monitor oxygen and combustibles for maximum fuel efficiency.more ...


WDG IV UOP WDG-IV UOP/RP

The UOP Continuous Catalyst Regeneration Process requires low-level continuous oxygen measurement during the regeneration process to protect the Platonized catalyst from oxidation. The process is operated at elevated temperature and pressure. The flue gas contains low levels of HCL and catalyst fines. The critical oxygen measurement analyzer must be able to survive the veracious nature of the process while maintaining a high level of accuracy at low level oxygen concentrations. more ...


WDG IVM IQ WDG-IVM

The WDG-IVCM analyzer measures oxygen, combustibles and methane in natural gas-fired applications. It is ideal for gas-fired power boilers or for those using natural gas during start-up and shutdown. With this analyzer, you can monitor oxygen and combustibles for maximum fuel efficiency. In addition, the methane detector can be used for purge and lightoff cycles during start-up and shutdown.more ...


CG1000 CG1000 Oxygen Analyzer

The CG1000 is a portable oxygen analyzer designed for industrial and laboratory applications. It has a wide operating range (0.1 ppm to 100% O2, autoranging), a fast response to oxygen changes, and advanced electronic capabilities for easy system integration. more ...


about us - news & resource center - customer support - sales contact - contact us - our applications - our products - our technology
©Copyright 2015 AMETEK, Inc. All Rights Reserved. www.ametek.com
privacy policy - trademarks - sitemap